Model IX-GA-2475(-D) IX-G-2475(-D) IX-GA-S-2462(-D) IX-GE-2462A(-D)
X-ray tube voltage 25/ 30/ 35/ 40/ 45/ 50/ 55/ 60/ 65/ 70/ 75kV 30/ 35/ 40/ 45/ 50kV
X-ray tube current 1 - 8.0 mA 1.0 mA
X-ray output MAX 300 W MAX 50 W
X-ray protection Protective curtain (rapidly detachable)
X-ray emissions 1 μSv/h or less, including conveyor entrance/exit
Product configuration With or without packaging
Inspection
chamber
Length 20 - 450 mm (intermittent flow)
Width Up to 240 mm
Height Up to 120 mm
Conveyor Material FDA approval type urethane belt (white)
Dimensions 800 mm (L) × 270 mm (W)
* + 100mm at follower side is available as an option
800 mm (L) × 270 mm (W)
Speed Standard type: 10 - 60 m/min. (Option for 2475 model: 15 - 90 m/min.)
Sanitary type (-D): 10 - 60 m/min.
Conveying
Weight
Standard type: MAX 2 kg (over entire length) (Option for 2475 model: 4 kg, but at 10 - 30 m/min. belt speed)
Sanitary type (-D): MAX 2 kg (over entire length)
Cooling method Hermetical air cooling Compulsory air cooling Heat sink cooling
Power supply AC200/ 208/ 220/ 230/ 240V, 50/60Hz Voltage variation: +/– 10%
Protective construction IP65 (Conveyor unit: IP66) (Conveyor unit: IP66) IP54 (Conveyor unit: IP66) IP65 with optional air cooler (Conveyor unit: IP66)
Operation temperature 0°C - 40°C ambient temperature (with no freezing or rapid temperature shifts) 0°C- 35°C ambient temperature (with no freezing or rapid temperature shifts) 0°C - 33°C ambient temperature (with no freezing or rapid temperature shifts)
Operation humidity 30 - 85%RH (with no condensation)